Panasil® Monophase Medium is a medium-consistency precision impression material with high tear resistance. Panasil® Monophase Medium has been specially developed for, among others, all your crown, bridge and implant work. Panasil® Monophase Medium is designed for the monophase impression technique, but can also be combined in the one-step impression technique with Panasil® initial Light and/or X-Light. With unique flow and thixotropic properties.
Panasil® Monophase Medium is available as a 380 ml jumbo cartridge and in the optimised 50 ml cartridge system. Panasil® Monophase Medium is also highly suitable as an impression material for the edentulous patient.
Precision without compromise, that is what the Panasil® Family stands for. The range includes the right product for every impression technique and indication. Impressive product properties and well-matched product combinations ensure the desired final result. The Panasil® family is available in X-Light, Light, Medium, Heavy and Putty (hand-mix & mixing device) consistencies.
All Panasil® products are A-silicone materials.
Impression Steps
Also check out our educational instruction videos and further information!
| Indications | Crown and bridge impressions – one-step technique, Implant impressions in dentate patients, Implant impressions in edentulous patients, Impressions of edentulous patients |
|---|---|
| Impression technique | Non-pressure impression (edentulous), Single-phase crown and bridge work |
| Shore hardness | A 60 (ca.) |
| Intra-oral setting time (≥ 35 °C) | 1 minute and 10 seconds |
| Colour | Blue |
| Application method | Applyfix 4 dispensing gun, Mixstar, Pentamix 1, Pentamix 2, Pentamix 3, Plug & Press dispenser, Sympress / Sympress II or other automatic dispensing and mixing device |
| Type of material | Addition silicones (PVS) |
| Consistency | Medium / Type 2 |
| Impression tray selection (recommendation) | Closed tray |
| Type of packaging | Cartridges 2 x 50 ml, Intro 380 ml, Refill 2 x 380 ml |
| Setting time | Normal |
| Content | 2 pieces |
| Brand | Kettenbach Dental |
| Manufacturer | Kettenbach GmbH & Co. KG |
The content has the same quality you are used to from Kettenbach Dental. You still benefit from the excellent properties of Kettenbach Dental impression materials. Once again, thanks to the new 380 ml Jumbo white cartridge with the matching white dynamic mixing tip, your mixing result is guaranteed. Due to the special cartridge neck, the impression material can be used immediately and the so-called “pre-bleeding” is not necessary.
No worries, they will simply retain their value!
You have either already received the equivalent number of new white dynamic mixing tips free of charge for exchange, or you are still entitled to an exchange. For this, you can contact us directly at ln.4latned@ofni.
Unfortunately, the blue dynamic mixing tips do not fit these new white 380 ml Jumbo cartridges and vice versa. Therefore, you can order one pack of new white dynamic mixing tips free of charge from your dental depot or from us, so that you will not be faced with any surprises now or in the near future.
The colour of a cartridge’s end cap also indicates the colour of the corresponding mixing tips’ diameter. However, a certain diameter/colour mixing tip may be available in different lengths. This is never an option, as the length of the tip containing the integrated mixing mechanism guarantees complete mixing of a certain material. To be on the safe side, always choose the manufacturer’s original mixing tips. There are now many imitation mixing tips on the market that often do not mix correctly, which can lead to printing inaccuracies.
Latex has a negative effect on the curing of A-silicones and Identium. Contact with latex can prevent impression material from curing properly or at all in certain areas. This results in impression errors that are often immediately visible in the impression. Fortunately, latex-free practices have been standard in dentistry and dental prosthetics for many years. However, due to the acute shortage of gloves during the COVID-19 pandemic, latex gloves have been reintroduced alongside nitrile and vinyl gloves, resulting in reports of latex-related impression errors.
First bring the impression materials to room temperature (processing and curing times are affected by higher or lower temperatures). Do not use latex gloves or a polyether “contaminated” impression syringe. First remove the inhibition layer (lubricating layer) from an individual tray before taking an impression. When using a hand mix A-silicone Lab putty, always use the same ratio of catalyst and base material.
Temperature (warmer or colder than room temperature), latex and a polyether “contaminated” impression syringe, but also the inhibition layer (lubricating layer) of a temporary restoration material that has remained on the preparation. Furthermore, some retraction agents may have a negative effect on curing; we have not received any complaints about this with regard to Kettenbach impression materials for decades. With a hand-mixed A-silicone putty, it is important that the ratio of catalyst to base material is 50/50% – if this is not the case, not only will the times mentioned change, but also the technical properties of the putty impression material.
When selecting a ready-made tray, it is important to choose a well-fitting, rigid tray and customise it if desired. To create sufficient pressure with medium (Type 2) and heavy body (Type 1) impression material, choose a closed impression tray. By choosing a full impression tray instead of a partial tray, the laboratory obtains the desired dental information.
Impression material shrinks (minimally) and in order to make this shrinkage predictable and controllable, it is important to be able to create an even impression material thickness between the elements and the inside of the impression tray. Because adhesion occurs between the tray and the impression material, this material shrinkage always occurs towards the tray wall. The more shrinkage the impression material has, the greater the cement thickness will be when placing the crown and bridge work. An individual tray for a dentate situation must have sufficient impression material space (at least 4 to 5 mm).
It is important to note that a good individual tray can only be made thanks to a correct preliminary impression with alginate or Silginat® (scan-optimised A-silicone impression material). If trays are to be printed, it is preferable to make the preliminary impression with a scan-optimised impression material. For crown and bridge work, it is important that the tray is not too tight; in addition to blocking out undercuts, sufficient impression space (at least 4 to 5 mm) must also be created. Any inhibition layer on the plastic individual tray can interfere with the curing process of the impression material and must be thoroughly removed before use. After checking the fit, use the appropriate tray adhesive (also just over the edges). An adhesive only has a good adhesive effect once the adhesive layer is dry (after approximately 4 minutes).
Important steps for making a good impression start with preparing the impression tray, selecting the appropriate tray, customising it if necessary, and coating it with the appropriate adhesive, including over the edges. The adhesive will have dried completely by the time the impression is taken, ensuring a secure bond. Tip: if there is a risk of bleeding, take a second impression with a partial tray immediately after removing the mouthpiece. The pressure during the first impression reduces the risk of bleeding. Prepare the mixing gun/syringe/device for use and set the timer to the desired total curing time. The practitioner and assistant should be ready to start spraying the preparation and filling the impression tray simultaneously. Important: remove any retraction cord or paste and cotton rolls from the patient’s mouth just before taking the impression.
Prevent poor impressions by first eliminating any external factors that could adversely affect the processing and curing times of the impression material. These include temperature (warmer or colder than room temperature), latex, a polyether “contaminated” impression syringe, and the inhibition layer (lubricant layer) of temporary restoration material left on the preparation. Furthermore, some retraction agents may have a negative effect on the curing of the impression material; we have not received any complaints about this with regard to Kettenbach impression materials for decades. Use rigid impression trays and ensure that they are coated with the correct tray adhesive; the adhesive must be dry before the tray is filled with impression material. For sufficient pressure build-up with a medium and heavy body consistency, use a closed tray (putty in a perforated tray). With an individual impression tray, ensure sufficient impression space (4 to 5 mm) and remove any inhibition layer. Important: remove retraction cord or paste and any cotton rolls from the patient’s mouth just before taking the impression.
Begin the best preparation for printing by first determining the tray selection and individualising it if necessary. Coat the trays with adhesive before preparation; also just over the edges (adhesive must be dry for the adhesive effect). Prepare a partial tray so that, if desired, a second impression can be made immediately after removal. Due to the pressure during the first impression, there is a good chance that any bleeding will be under control. Prepare the mixing gun/syringe/device for use and set the timer to the desired total curing time. The practitioner and assistant should be ready to start spraying the preparation and filling the impression tray simultaneously.
Important: remove retraction cord or paste and any cotton rolls from the patient’s mouth just before taking the impression.
It is always best to store printing materials in a place that is neither too warm nor too cold. Since printing materials should be used at room temperature, it is wise to choose a place/room for storage that does not deviate too much from the desired room temperature. If this does happen, bring the printing materials to room temperature before use. If the printing material is too cold during printing, the curing times will be longer than stated, and if you are working in a (too) warm room, the processing and curing times will be much faster than normal.
Before printing can begin, any bleeding must be brought under control. Some retraction materials can have a negative effect on the hardening process of the impression material; we have not received any complaints about this with regard to Kettenbach impression materials for decades. Remove retraction cord or paste and any cotton rolls from the patient’s mouth just before taking the impression.